General Mobile Clinics · TANZANIA PROJECT CONFIGURATION
Sinotruk Large Mobile Examination & Treatment Vehicle
A large mobile examination vehicle with space for outreach health checks and emergency-treatment support.
Core capabilities in operation
Translate vehicle and medical-cabin data into a real project decision. Final performance depends on route, patient-care role, installed equipment and the signed technical schedule.
| Parameter | Procurement meaning | Confirm before order | What changes the result |
|---|---|---|---|
| 6×2 class stated by linked source family; exact axle layout to confirm | Delivers the source-stated mobile health mission | Approve RHD chassis, workflow, layout and payload before production | Route, patient flow, crew, devices and power |
| Source record states medical equipment but does not itemise devices; examination rooms, privacy, power and equipment interfaces must be defined in the signed schedule. | Project-specific medical conversion | Itemise rooms, devices, utilities, restraints and storage in the contract | Programme scope, privacy, accessibility and maintenance |
Technical specifications
| Manufacturer | Chengli Special Automobile Co., Ltd. |
|---|---|
| Vehicle model | CL5120XYL6BZ Mobile Examination Vehicle |
| Chassis | Sinotruk Large vehicle / Weichai power platform; exact chassis code to confirm |
| Drive type | 6×2 class stated by linked source family; exact axle layout to confirm |
| Fuel / energy | Diesel |
| Transmission | Manual |
| Engine power | Weichai Power 8.350E61 source description; output to confirm |
| Wheelbase | 5800 / 6100 / 6300 mm options stated |
| Overall dimensions | 9025 or 8995 × 2550 × 3950 mm |
| Gross vehicle weight | 12005 kg |
| Steering side | Left-hand drive is stated in the source description; a documented RHD chassis is required for Tanzania |
| Medical role | Examination/outreach workflow is contract-defined |
| Stretcher capacity | Not a default acceptance criterion; confirm only if required by programme |
Published base data supports selection only. The signed chassis, conversion and medical-equipment schedules take precedence.
Medical cabin specifications
| Cleanability | Confirm surfaces, joints, floor and infection-control method |
|---|---|
| Equipment | Source record states medical equipment but does not itemise devices; examination rooms, privacy, power and equipment interfaces must be defined in the signed schedule. |
| Workflow | Define patient flow, staff positions, privacy and accessibility |
Oxygen system
| Confirmation | Confirm capacity, reserve, mounting and outlets if included |
|---|---|
| Scope | Only required where the selected clinical programme needs it |
Electrical system
| Confirmation | Approve input voltage, distribution, protection, battery/inverter/generator and autonomy |
|---|---|
| Scope | Medical devices, lighting, cooling and shore power require a load review |
Safety and restraint configuration
| Inspection | Verify axle loads, stability, fire safety and emergency egress |
|---|---|
| Occupants | Confirm belted seating, exits and equipment retention |
| Rhd | Left-hand drive is stated in the source description; a documented RHD chassis is required for Tanzania |
Standard equipment
- Source-stated scope: Source record states medical equipment but does not itemise devices; examination rooms, privacy, power and equipment interfaces must be defined in the signed schedule.
- Base vehicle: Sinotruk; Sinotruk/Weichai large vehicle platform; exact chassis code to confirm; Diesel; Manual
Configuration options and trade-offs
- Clinical breadth: More rooms and devices increase mass, energy, maintenance and training needs.
- Vehicle size: Larger bodies improve workspace but reduce access and require route and stability review.
Operating fit
Suitable conditions
- Outdoor health checks, occupational health programmes, community outreach and medical support at events.
- Programmes with a defined workflow, utilities and trained operators
Not recommended for
- Deployment before RHD, route, power and destination checks are complete
- Use of unlisted regulated devices without registration, calibration and service evidence
Programme positioning
A large mobile examination vehicle with space for outreach health checks and emergency-treatment support.
Outdoor health checks, occupational health programmes, community outreach and medical support at events.
Verified source data
Model: CL5120XYL6BZ Mobile Examination Vehicle. Chassis: Sinotruk/Weichai large vehicle platform; exact chassis code to confirm. Drive: 6×2 class stated by linked source family; exact axle layout to confirm. Fuel: Diesel. Transmission: Manual. Dimensions: 9025 or 8995 × 2550 × 3950 mm. GVW: 12005 kg. Wheelbase: 5800 / 6100 / 6300 mm options stated. Power: Weichai Power 8.350E61 source description; output to confirm.
Source record states medical equipment but does not itemise devices; examination rooms, privacy, power and equipment interfaces must be defined in the signed schedule.
Before procurement approval
Confirm RHD, route access, payload and axle loads, clinical workflow, utilities, device list, registration responsibilities and Tanzania documentation in the signed technical schedule.
Frequently asked questions
Which medical devices are included?
Only the source-stated scope is summarized. Device brands, models, quantities, registration, calibration and service responsibilities must be listed in the quotation.
Is the vehicle ready for Tanzania?
Not yet confirmed. The exact RHD chassis, route fit, power system and Tanzania documentation require order-specific approval.
Verification and procurement support
Vehicle data is mapped from the available product record. Final RHD chassis identity, emissions, patient-compartment layout, medical devices, documents and Tanzania destination requirements must be confirmed in the signed technical schedule.
- Base VehicleListed parameters mapped from source
- Clinical ScopeOnly source-stated functions are summarized; device schedule remains contract-defined
- IdentitySource product ID, title and category checked
- Images6 unique source-gallery URLs retained